heatstress

Heat stress indices in Python: NWS heat index, WBGT (Liljegren), UTCI, humidex, apparent temperature, wet bulb, wind chill, ACGIH work-rest and heatwave / Excess Heat Factor detection.

Version 0.1.2 · Python >=3.9 · MIT licence
pip install heatstress
PyPISourceIssuesChangelogCite (DOI)

heatstress

PyPI version Python versions pipeline status License: MIT DOI Downloads

Heat-stress indices from ordinary weather data, for public-health, climate-adaptation and occupational-safety work: NWS Heat Index, Humidex, Apparent Temperature, wet-bulb temperature, WBGT (full Liljegren et al. 2008 model, shade/indoor, ISO 7243, BoM approximation), UTCI, Wind Chill, mean radiant temperature, solar position, risk categories and heatwave detection, including the Excess Heat Factor.

Installation

pip install heatstress            # numpy only
pip install "heatstress[pandas]"  # + pandas helpers (DataFrames, events_to_frame)
pip install "heatstress[xarray]"  # + xarray/pandas

Python 3.9 or newer.

Quick start

import heatstress as hs

hs.heat_index(35, 60)                     # 45.1 degC (NWS algorithm)
hs.heat_index_category(45.1)              # 'danger'
hs.utci(30, tmrt=50, wind=2, rh=50)       # 34.6 degC, 'strong heat stress'

# Outdoor WBGT from standard weather data (Liljegren et al. 2008)
z = hs.solar_zenith("2026-07-15T10:00Z", lat=38.42, lon=27.14)
w = hs.wbgt_liljegren_components(t=33, rh=55, wind=1.5, solar=850, zenith=z, pressure=1008)
w.wbgt, w.globe_temperature, w.natural_wet_bulb    # 32.7, 49.7, 27.7 degC
hs.work_rest_allocation(w.wbgt, "moderate")       # ACGIH TLV work-rest guidance

Features

Disclaimer. heatstress computes screening indices from weather data. It is not medical advice and is not a substitute for on-site measurement, an occupational health programme, clinical judgement or the official warnings of your national meteorological or public-health service.

More examples

import numpy as np
import pandas as pd
import heatstress as hs

hs.heat_index(95, 50, units="F")          # 105.2 degF
hs.humidex(30, dew_point=15)              # 34.0
hs.apparent_temperature(30, 50, wind=2)   # 31.6 degC
hs.wet_bulb_psychrometric(25, 50)         # 17.9 degC
hs.utci_category(34.6)                    # 'strong heat stress'

# Heatwaves on a daily series (synthetic data here; use your own station record)
days = pd.date_range("1991-01-01", "2020-12-31", freq="D")
rng = np.random.default_rng(0)
tmax = pd.Series(22 + 10 * np.sin(2 * np.pi * (days.dayofyear - 110) / 365.25)
                 + rng.normal(0, 3, len(days)), index=days)
thr = hs.calendar_day_percentile(tmax, tmax.index, q=90, window=15, baseline=(1991, 2020))
events = hs.heatwave_events(tmax, thr, min_duration=3)
hs.events_to_frame(events)

ehf = hs.excess_heat_factor(tmax - 6)     # daily mean temperature; Nairn & Fawcett (2015)
hs.ehf_severity(ehf)                      # none / low-intensity / severe / extreme

Indices

Index Function Inputs Source Validity / notes
Heat Index heat_index T, RH NWS/WPC algorithm: Steadman (1979) simple formula, Rothfusz (1990) regression and the two NWS adjustments Regression error +/-1.3 degF; warning above 120 degF air temperature or 150 degF HI
Rothfusz regression only rothfusz_regression T, RH Rothfusz (1990) NWS SR 90-23 For comparison only
Humidex humidex T, RH or dew point Masterton & Richardson (1979), Environment Canada MSC vapour-pressure form
Apparent Temperature apparent_temperature T, RH, wind (10 m), optional net radiation Steadman (1994), Australian Bureau of Meteorology Shade and radiation forms
Wet bulb (Stull) wet_bulb_stull T, RH Stull (2011) J. Appl. Meteor. Climatol. 50:2267 RH 5-99 %, T -20 to 50 degC, 1013 hPa; error -1 to +0.65 K (larger in cold, dry air)
Wet bulb (psychrometric) wet_bulb_psychrometric T, RH, pressure WMO No. 8 (2018) Annex 4.B psychrometer equation, Newton solver Ventilated wet bulb, wick over water
WBGT outdoor wbgt_liljegren, wbgt_liljegren_components, globe_temperature_liljegren, natural_wet_bulb_liljegren T, RH, wind, global solar, zenith, pressure, optional direct fraction Liljegren et al. (2008) J. Occup. Environ. Hyg. 5:645 50.8 mm globe; 2 m wind (other heights scaled with a power law); solar capped at 0.85 x top of atmosphere as in the reference code
WBGT shade / indoor wbgt_shade T, RH, pressure (wind for method="liljegren") Simplified 0.7 Tw + 0.3 Ta, or Liljegren with no sun and 0.7 Tnwb + 0.3 Tg No solar load
WBGT from measurements wbgt_from_measurements Tnwb, Tg, (Ta) ISO 7243:2017 Indoor and outdoor formulas
WBGT approximation wbgt_bom T, RH Australian Bureau of Meteorology Approximation: assumes moderately high radiation and light wind; can be off by several degrees
UTCI utci T, Tmrt, wind (10 m), RH Broede et al. (2012) Int. J. Biometeorol. 56:481, 6th-order polynomial, 210 coefficients from the reference program UTCI_a002.f90 Ta -50 to 50 degC, Tmrt-Ta -30 to 70 K, wind 0.5-17 m/s, vapour pressure <= 5 kPa; out-of-range values NaN by default; wind below 0.5 m/s raised to 0.5
Wind Chill wind_chill T, wind (10 m) NWS/MSC (2001), Osczevski & Bluestein (2005) T <= 10 degC; MSC light-wind formula below 4.8 km/h
Feels like feels_like T, RH, wind NWS convention Wind chill / heat index / air temperature
Mean radiant temperature mean_radiant_temperature Tg, T, air speed ISO 7726:1998 Annex B Forced or natural convection; 150 mm globe, emissivity 0.95 by default
Solar position solar_position, solar_zenith time, lat, lon NOAA solar calculator (Meeus 1991) Geometric zenith, no refraction
Humidity helpers saturation_vapour_pressure, vapour_pressure, dew_point, relative_humidity_from_dew_point, relative_humidity_from_vapour_pressure T, RH / Td / e Magnus (Alduchov & Eskridge 1996), WMO, Buck (1981), BoM, Hardy (1998) ITS-90 Over liquid water

Risk categories

Function Scale
heat_index_category NWS: caution 80-89 degF, extreme caution 90-102, danger 103-124, extreme danger >= 125
humidex_category Environment Canada: < 30, 30-39, 40-45, >= 46
utci_category 10 UTCI stress classes from extreme cold (< -40) to extreme heat stress (> 46)
work_rest_allocation ACGIH TLV (acclimatized) / Action Limit (unacclimatized) WBGT work-rest table as printed in the OSHA Technical Manual Sec. III Ch. 4, for light / moderate / heavy / very heavy work, with a clothing adjustment value
iso7243_reference_wbgt, iso7243_assessment ISO 7243:2017 Annex A reference WBGT 56.7 - 11.5 log10(M) (acclimatized) and 59.9 - 14.1 log10(M) (unacclimatized)
ehf_severity Nairn & Fawcett (2015): low-intensity, severe (EHF >= EHF85), extreme (EHF >= 3 EHF85)

Heatwave detection

Command line

$ heatstress hi 35 --rh 60
              heat_index: 45.1 degC
                category: danger

$ heatstress wbgt 33 --rh 55 --wind 1.5 --solar 850 --time 2026-07-15T10:00Z --lat 38.42 --lon 27.14
$ heatstress utci 30 --tmrt 55 --wind 2 --rh 50
$ heatstress windchill 0 --wind 15 --wind-units mph --units F
$ heatstress series weather.csv -o indices.csv --lat 38.42 --lon 27.14

Every value command accepts --units C|F|K and --json; wind accepts --wind-units ms|kmh|mph|kn. heatstress series reads a CSV, recognises common column names (time, t/temperature, rh, td, wind, solar/ghi, pressure, tmrt, tg, zenith, lat, lon), and appends every index that the columns allow (UTCI needs tmrt or a globe temperature; the Liljegren WBGT needs wind, solar and either a zenith column or time plus coordinates). The same logic is available in Python as hs.compute_indices(df).

Validation

All comparisons are in the test suite (tests/test_reference_values.py) unless noted.

Check Reference Result
UTCI polynomial 1000 official test conditions, Broede et al. UTCI-Test-Data (doi:10.5281/zenodo.5503968, CC BY 4.0), column UTCI_polynomial max deviation 0.050 degC (= rounding of the published values)
UTCI vs UTCI-Fiala model same data set, 921 cases with wind <= 17 m/s RMS 1.17 K (Broede et al. report about 1.1 K)
UTCI vs independent code thermofeel 2.3.0 calculate_utci_polynomial max 1e-12 degC (scratch cross-check)
Heat index vs NWS chart 135 cells of the NWS heat index chart bare Rothfusz regression within 0.92 degF; full NWS algorithm within 0.92 degF where no adjustment applies and within 2.29 degF in the high-humidity cells where NWS adds its adjustment
Heat index vs independent code thermofeel calculate_heat_index_adjusted, 5000 random cases T <= 43 degC max 0.08 degC (scratch cross-check)
Liljegren WBGT, globe, natural wet bulb thermofeel 2.3.0 thermofeel.liljegren (KNMI port of the reference C code), 3000 random cases max 4e-13 degC; 8 frozen vectors in the tests
Wet bulb Stull (2011) worked example 20 degC / 50 % -> 13.7 degC; psychrometric table 25 degC / 50 % -> 17.9 degC exact to the published precision; Stull vs psychrometric within +/-1 K for 0-45 degC, RH 20-95 %
Wind chill NWS wind chill chart (6 cells); thermofeel within 0.6 degF; identical to thermofeel
Humidex Environment Canada example 30 degC / Td 15 degC -> 34 exact; thermofeel max 0.04
Apparent temperature thermofeel calculate_apparent_temperature identical (scratch cross-check)
Mean radiant temperature ISO 7726 formula; thermofeel max 0.06 degC (thermofeel uses 273.15 K in place of ISO's 273)
Solar position pvlib 0.16.1 NREL SPA, 4000 random times 1990-2060 and latitudes +/-80 deg zenith max 0.017 deg, Earth-Sun distance max 7e-5 AU; 6 frozen cases in the tests
Excess Heat Factor thermofeel thermofeel.excess_heat with pandas rolling windows max 4e-11

Units and conventions

Citation

@software{eminoglu_heatstress,
  author  = {Eminoğlu, Yusuf},
  title   = {heatstress},
  year    = {2026},
  version = {0.1.2},
  doi     = {10.5281/zenodo.24065186},
  url     = {https://doi.org/10.5281/zenodo.24065186}
}

See CITATION.cff. Please also cite the original authors of each index you use.

Related Geophilo SDKs

License

MIT (c) 2026 Yusuf Eminoğlu. The UTCI test data shipped in tests/data are by Broede et al., CC BY 4.0.